Manufacturers of Data Acquisition (DAQ) Systems (Boards, Data Loggers, ICs, SoC, etc.)
Looking for DAQ products ? Visit also our Online Store
List of DAQ Systems Manufacturers: |
Sponsored Links: |
||
|
|
USTI - Series of Universal Sensors and Transducers Interface ICs, 0.05 Hz - 9 MHz (144 MHz); programmable accuracy 1...0.0005 %; I2C, SPI, RS-232 interfaces
USTI-EXT - Series of Universal Sensors and Transducers Interface with extended temperature range ( - 55 0C to +150 0C), reduced conversion speed (from 6.25 ms to 12.5 ms for relative errors from 1 % to 0.0005 % respectively) and increased baud rate for the RS232 serial interface: up to 76 800.
Universal Frequency-to-Digital Converter (UFDC-1) and its high speed version (UFDC-1M-16); custom designed ICs of converters, sensors and transducers interfaces; physical and chemical sensor systems for European customers |
|
|
UFDC-1 - 2-channel high performance one chip data acquisition system for frequency-time parameters of signals (sensor outputs): frequency, period, duty-cycle, duty-off factor, PWM, time interval, pulse width and space, frequency (period) ratio and difference, phase-shift, events counting, rotation speed; 0.05 Hz - 7.5 MHz (120 MHz); programmable accuracy 1...0.001 %; I2C, SPI, RS-232 interfaces UFDC-1M-16 - 2-channel fast high performance one chip data acquisition system for frequency-time parameters of signals (sensor outputs): frequency, period, duty-cycle, duty-off factor, PWM, time interval, pulse width and space, frequency (period) ratio and difference, phase-shift, events counting, rotation speed; 1 Hz - 7.5 MHz (120 MHz); programmable accuracy 1...0.001 % and non-redundant conversion time from 6.25 ms to 6.25 ms; I2C, SPI, RS-232 interfaces EVAL-UFDC-1/UFDC-1M-16 |
||
|
T24-PA - wireless pulse acquisition module. Input frequency range 0.5 Hz ... 3000 Hz, relative error 0.15 ... 0.25 %; transmits on license free 2.4GHz; 100 / 200 m range depending on antenna | ||
|
AS8500 - a complete, low power multi purpose data acquisition system for very small signals (i.e. voltages from shunt resistors, thermocouples), 16-bit resolution, 3-wire serial interface AS8501 - High Performance Data Acquisition System, 16-bit resolution, 3-wire serial interface |
||
|
Picosecond-Timing System - a flexible, TDC-GPX based timing processing platform for time interval and event timing applications. 10 ps resolution; 8 channels for multi-stop input signal's processing; 1 common start input | ||
JLM Innovation |
|
FQ4 - 4 channel measurement instrument for QMB and SAW sensors. Frequency input up to 500 MHz with simultaneous, continuous measurement of all channels |
|
|
ME-1400 and MEphisto Digi - Counter & digital I/O board for PCI, PXI/CompactPCI, USB. Up to 3, 6, 15 or 30 counters. 16 bit counters compatible with 8254.1 or 10 MHz selectable clock; quartz oscillator accuracy 0.01 % (100 ppm)ME-8100 - opto-isolated digital and counter board. 3x 16 bit counters, external counter clock up to 1 MHz ME-Jekyll ME-4610 - High-precision, low-price 16 bit standard DAQ board. 3x16 bit countersME-FoXX ME-46xx - High-precision 16 bit multifunctional DAQ board. 3x16 bit counters |
||
|
DRP 8500 - Series Low Cost Analog to Frequency Modules for Micro PLC Digital Inputs. (Current-, voltage-, thermocouple-, RTD- and strain gage-to-frequency converters); 0 - 5100 Hz frequency ranges D1000 and D2000 - digital transmitters with frequency, time and event inputs iDRX - programmable signal conditioners/transmitters with frequency input (0-50 kHz; 0.1 % FS) iFPX - Internet Counter iServer MicroServer (1 Hz - 100 kHz; 0.3 % totalizer accuracy) INET Series - instruNet Series Direct Sensor to Data Acquisition with 10 Counter/Timer channels OMB-DAQBOARD-2000 Series - modules with counter/timers |
||
|
XXXF70 - Analog-to-Frequency Converter. Converts an input current, an input voltage or the signal from a sensor (thermocouple, Pt-100, resister, measurement bridge, etc.) into a frequency, which is proportional to the magnitude of the input signal. Maximum output frequency 20 kHz. Accuracy 0.02 % VFM 90 - voltage-/current-to-frequency converter. Input: 0-20 mA, 4-20 mA, 0-10 V; output 5 kHz, 10 kHz, 20 kHz |
||
|
M=BUS Logger 6C - 6 channel data acquisition unit; Transducer Electronic Data Sheet (TEDS); 16 bit resolution; 20 kHz sampling rate. Optimized for all applications in the field of impact testing | ||
|
mCAN.4.ci-BOX - 4-channel field modules, counter, 1Hz - 500 kHz, accuracy ± 0.1 Hz, high speed CAN interface 2.0A and 2.0B µCAN.4.ci-SNAP - 4-channel counter up to 500 kHz |
||
|
AFCM - analog to frequency or PWM converter module. input signal ranges are 0 to 20 mA, 4 to 20 mA, 0 to 10 V, 2 to 10 V, 0 to 5 V, and 1 to 5 V. Output frequencies are selectable in ranges up to 10 KHz. Transmission error < 0.1 % | ||
|
6746B - Programmable transmitter with frequency output; Thermocouples, RTD sensors; Process inputs (V, mV, mA), IR-thermopile; output 0 ... 2.5 kHz | ||
|
CNL48/F - programmable digital converter; all process and temperature inputs (V, mV, mA, power supply sensor, potentiometer, thermocouple,PT100, ...), frequency output |
||
|
8505, 8506, 8507 - Analog to frequency converters. The 4 to 20 mA input Model 8505 provides 1 kHz to 5 kHz output frequency for a 4 μA per Hertz resolution. The Model 8506 voltage input is scaled for 1 mV per Hertz to 5 kHz for 5 volts. The Model 8507 voltage input is scaled for 2 mV per Hertz to 5 KHz for 10 volts input. The output for all modules is linear to 0.01% with accuracy of better than 0.1% 8555 - analog to frequency converter for strain gages based load cell or pressure transducer outputs. The accuracy of better than 0.1% |
||
|
TWN-FO and TWI-FO - PLC Input Transmitters. Convert and analogue signal (4~20 mA and voltage) into a linear, frequency output signal (10~1010 Hz). Other calibrations available. Accuracy ±0.1 % FSO | ||
![]() |
MAQ20-FREQ - Frequency Input Module for Industrial Data Acquisition & Control Modular System. 4 channels, 500 Hz to 100 kHz TTL input, ±0.05 % Span | ||
|
MAXQ7665 - smart systems-on-a-chip (SoC) are data-acquisition systems based on a microcontroller (µC). Provides the most integrated system solution for processing magnetic sensor output signals in automotive and industrial applications MAXQ7666 is a smart data-acquisition system based on the low-power, MAXQ20 RISC microcontroller |
||
|
MCP3905A - active power to pulse converter (Energy Measurement IC), 0.1 %, 500:1 dynamic range MCP3906A - active power to pulse converter (Energy Measurement IC), 0.1 %, 1000:1 dynamic range MCP3909 - active power to pulse converter with SPI interface with simultaneous active power pulse output |
||
MEGATRON |
|
MIFN - Converts analog signals: current/voltage DC , temperature (PT-100 sensor) to 6 Hz - 1 KHz pulses. Accuracy 0.5 % F.S. MATP - Converts analog signals: 4-20mA / 0-60mV DC etc.to pulses 0.01 Hz up to 1 KHz MADO - Converts analog signals: 4-20mA DC / 0-60mV DC etc../ 0-5A AC to pulses 0.01 Hz up to 10 KHz |
|
|
ADwin-light-16 - real-time system; optional configuration: 2x32-bit counter, event, period, duty-cycle, PWM ADwin-Gold - real-time system; optional configuration: 2x32-bit counter, event, period, duty-cycle, PWM ADwin-Pro - contains 32 -bit counter, period, PWM analysis, pulse width, duty-cycle measurement |
||
|
APCI-1710, CPCI-1710 - multifunctional counter boards: frequency, period, pulse width measurements | ||
|
imc C-Series - intelligent, compact measurement system with 4 incremental inputs; TEDS. | ||
|
Read more about DAQ systems
|
1999 - 2020 Copyright ©, International Frequency Sensor Association (IFSA). All Rights Reserved.
Home - News - Links - Archives - Tools - Voltage-to-Frequency Converters - Standardization - Patents - Marketplace - Projects - Wish List - e-Shop - Sensor Jobs - Membership - Videos - Publishing - Site Map - Subscribe - Search
Members Area -Sensors Portal -Training Courses - S&T Digest - For advertisers - Bookstore - Forums - Polls - Submit Press Release - Submit White Paper - Testimonies - Twitter - Facebook - LinkedIn